TRANSMISSION // 2611.34433v1

Equivalent quantum circuits, different lab results

Source published

A three-qubit NMR experiment finds that logically equivalent ways of compiling a probability-loading circuit can produce different measured distributions, with results that vary across targets and runs.

AI-generated conceptual illustration for Equivalent quantum circuits, different lab results
AI-generated conceptual illustration; not documentary evidence.

A quantum circuit can have more than one gate-by-gate form while representing exactly the same ideal operation. Does that make the alternatives interchangeable on real hardware? A preprint testing a three-qubit NMR processor finds that the answer can depend on the circuit and the experimental run.

The question: does compilation matter after the maths is settled?

Quantum algorithms are written as operations, but hardware executes sequences of physical pulses and gates. A compiler can turn one ideal operation into different gate sequences that are mathematically equivalent. On imperfect hardware, those sequences need not behave alike: their gate order and timing may affect the errors that accumulate.

The study examines this issue in a specific task: loading a probability distribution into a quantum state. The authors use the ancilla-free Grover–Rudolph construction, which creates the desired probabilities through controlled rotations. Their focus is not just whether the measured output matches its target, but whether that accuracy changes when the same ideal operation is compiled differently.

What they did

The researchers implemented circuits on a three-qubit liquid-state nuclear magnetic resonance (NMR) processor. In one comparison, they used two Gray-code versions of a level-2 uniformly controlled rotation, labelled A and B. The versions use the same rotation angles and implement the same unitary operation, but order the CNOT controls differently.

They report 700 runs across seven target distributions for this comparison. Two additional experimental campaigns examined differences within a single unit. These included removing gates that are equivalent to the identity, thereby changing the executed schedule without changing the ideal operation, and changing how two inverse rotations were expressed while leaving the gate list unchanged.

The main reported accuracy measure is classical fidelity between the target and measured probability distributions. This assesses the observed outcomes, not every property of the quantum state.

What they found

The A-versus-B comparison was statistically significant for three of the seven targets after a Holm correction, a procedure that adjusts for testing multiple outcomes. Crucially, there was no consistent winner: which version appeared better depended on the target.

The identity-equivalent-gate experiment showed a different kind of dependence. Removing those gates affected A and B differently. The authors report an interaction of +0.0625, with a 95% confidence interval from +0.0306 to +0.0944 and a paired p-value of 4.8 × 10⁻⁴. The interaction reversed the sign of the A/B advantage. Across five acquisitions of this one logical circuit, the measured contrast ranged from +0.0395 to −0.0229.

Not every change mattered in the same way. On one target in one session, expressing two level-1 inverse rotations as 720° minus the angle rather than as the negative angle changed mean fidelity by −0.0006. The reported interval, from −0.0157 to +0.0146, includes zero, so this test does not establish a clear effect.

The authors also caution against treating classical fidelity as a complete description of performance. On the uniform target, they report classical fidelity of 0.962 alongside a two-body correlation of +0.217 where the target has no such correlation. They say the measured correlators are inconsistent with a global depolarising-noise description. In practical terms, a good match in output probabilities does not guarantee that other features of the quantum state are correct.

What remains uncertain

The authors favour the order and timing of the executed pulses as a hypothesis for why equivalent compilations behave differently, but they do not identify a mechanism. The findings therefore do not show that one general compilation strategy is best, or that the same effects will occur on other processors, circuit sizes or hardware technologies. Some comparisons are limited to one target, one session or a small number of acquisitions; the reported variation between acquisitions underlines the need for broader tests.

This account is based on the paper’s abstract, not a full-text assessment. The work is an arXiv preprint, and the available source information does not establish peer review. The authors say run-level data and code are deposited for every campaign run on their own unit, while the pulse-level campaign is reported from summary tables. Those details matter when assessing how completely the results can be independently checked.

The careful takeaway is narrow but useful: mathematical equivalence alone does not ensure identical measured performance in this experiment. Compiler choices may be part of the practical behaviour of a quantum circuit, and judging them requires more than checking the output probabilities.

Reviewed cross-references

These connections were reviewed by a model, not independently fact-checked by a human. Similarity does not imply agreement; consult the original papers and the evidence below.

  • Quantum cloud test shows why qubit counts are not enough

    Supporting evidence: Both studies show that hardware results reflect execution choices as well as the logical task: the origin paper’s controlled, three-qubit NMR intervention found that removing identity-equivalent gates changed the relative performance of equivalent circuits, while the GHZ benchmark describes compiler qubit selection as one contributor to its hardware-dependent score. The GHZ study does not isolate that contribution, so it is contextual support, not a direct replication or a comparable causal test.

    Model review: · openai-codex/gpt-6-luna

    Evidence and provenance

    Selected excerpts, not complete papers. PDF extraction can omit figures or damage equations, tables and reading order; sources may be preprints.

    • 2611.34433v1 — Original paper

      Excerpt reference: static/papers/2611.34433v1.md:1604-1657
      Basis: Paper text
      Source SHA-256: 107c9bb7b795c5bb3ea08c8a601e7b024a430a6c7e0627d8c1260a3f719eb5ca

    • 2611.14114v1 — Original paper

      Excerpt reference: static/papers/2611.14114v1.md:235-342
      Basis: Paper text
      Source SHA-256: 43d96faa1aa717f464c43a93b1541bf838218da6c08f8f91d8d46838ec80f9a3

Automatically matched by shared topic keywords. These links do not imply that the sources agree or establish a consensus.