TRANSMISSION // 2611.34008v1

DosePET opens a library of PET/CT radiation maps

Source published

DosePET releases 2,100 simulated, patient-specific radiation dose maps linked to PET/CT scans, giving researchers a shared resource to explore personalized dosimetry.

AI-generated conceptual illustration for DosePET opens a library of PET/CT radiation maps
AI-generated conceptual illustration; not documentary evidence.

A PET scan shows where a radioactive tracer is distributed, but estimating the radiation absorbed by different tissues also requires accounting for anatomy and how radiation travels through the body. DosePET offers researchers a collection of simulated dose maps tied to patient scans—a resource for developing and testing future dosimetry tools, not a clinical dose calculator.

Why build a dose-map dataset?

Positron emission tomography (PET) uses radioactive tracers to help reveal biological activity inside the body. The tracer emits radiation, and the amount absorbed varies with its distribution and the patient’s anatomy. Personalized dosimetry—the estimation of absorbed radiation for an individual—could support research into radiation protection and imaging protocols. But building a three-dimensional dose map for each examination can require substantial computation, and such maps have been scarce in public datasets.

In a preprint, Eleftherios Tzanis, Antonios Tzortzakakis and Michail E. Klontzas introduce DosePET, an open dataset of 2,100 patient-specific dose maps generated from publicly available PET/CT examinations. The researchers’ goal is to provide data that can help others develop and evaluate computational methods, including artificial-intelligence models, for estimating radiation dose in nuclear medicine.

From scans to simulated dose

The dataset draws on two existing collections: ENHANCE.PET and PSMA-PET-CT-Lesions. It includes 1,503 examinations using the tracer [18F]FDG, 369 using [18F]PSMA-1007 and 228 using [68Ga]Ga-PSMA-11. The scans came from five institutions and seven scanner models. The authors excluded 180 ENHANCE.PET examinations because their PET values were recorded as counts rather than in the quantitative units required by the processing pipeline.

For each included examination, the team aligned the CT image to the PET image’s grid. CT values were used to build a voxel-by-voxel model of the patient’s tissues, while the quantitative PET image supplied the simulated distribution of radioactive material. The researchers then used GATE, a radiation-transport simulation toolkit, to estimate energy deposited in the body. In plain terms, the simulation follows how radiation from the tracer interacts with the modeled tissues.

The team also used TotalSegmentator software to create masks identifying 117 organs and tissues from the CT scans. Those masks let users calculate regional quantities from the simulated maps. Each study folder contains a three-dimensional dose map, anatomical masks, a report of dosimetry measures and simulation metadata. The authors report that processing all examinations took 1,542.4 hours in total.

What the resource contains—and what it does not show

The maps represent absorbed dose in gray and are integrated from scan time to infinity. The authors provide tools to convert them into scan-time dose-rate maps or dose-per-decay maps. Their report also lists regional measures, including mean absorbed doses and dose conversion factors. The paper summarizes which anatomical regions had the highest median doses within each tracer group; these summaries describe this dataset and its modeling choices, not universal values for every patient or scan.

Several assumptions matter when interpreting the maps. The calculations use a single PET time point and assume that the tracer’s spatial distribution stays unchanged while its radioactivity declines through physical decay. They do not model biological clearance or redistribution, and activity outside the imaged area is not included. The maps also exclude dose from the CT scan. Optional estimates extending back toward injection time are model extrapolations, not measurements of how tracer uptake changed earlier.

These are simulated reference maps, not direct measurements of absorbed dose in patients. The authors describe the resource as a foundation for research; the paper does not demonstrate that a particular AI model trained on DosePET predicts dose accurately or improves clinical decisions. The masks are automatically generated, and users can instead apply manually drawn contours. The dataset includes repeated examinations for some participants, so examination counts should not be mistaken for counts of unique people.

DosePET is publicly available through Hugging Face, with Python utilities for downloading selected studies and converting maps. Its practical value will depend on how well researchers validate methods built with it and account for differences between the included scans and the cases where those methods might eventually be used.

The source is an arXiv preprint, a research manuscript shared before or outside formal journal peer review; its claims should be read with that limitation in mind. The dataset expands access to simulated PET/CT dosimetry data, but it does not by itself establish clinical performance or replace patient-specific clinical assessment.

Reviewed cross-references

These connections were reviewed by a model, not independently fact-checked by a human. Similarity does not imply agreement; consult the original papers and the evidence below.

  • A set-aware AI model estimates X-ray shielding in milliseconds

    Shared method: Both studies use Monte Carlo radiation-transport simulations: DosePET uses GATE 9.4 to generate patient-specific PET dose maps, while STAR-XPC uses PENELOPE/penEasy to generate X-ray transmission targets for a surrogate model. This is a shared simulation approach, not evidence that the models or results are comparable; the radiation sources, targets and simulation systems differ.

    Model review: · openai-codex/gpt-6-luna

    Evidence and provenance

    Selected excerpts, not complete papers. PDF extraction can omit figures or damage equations, tables and reading order; sources may be preprints.

    • 2611.34008v1 — Original paper

      Excerpt reference: static/papers/2611.34008v1.md:137-197
      Basis: Paper text
      Source SHA-256: 48c5aacdaa9583dd751121060f615c2b8970af30c011147000c8c0a0bdb100c6

    • 2610.28709v2 — Original paper

      Excerpt reference: static/papers/2610.28709v2.md:13-84
      Basis: Paper text
      Source SHA-256: 3464f7e231dba088915a0a988da156c6ab8b5b5cd0d166f1c8b238a2e0d1c870

Automatically matched by shared topic keywords. These links do not imply that the sources agree or establish a consensus.