TRANSMISSION // 2611.30459v1
Hera’s Mars flyby checks its asteroid-bound camera
Source published
Comparisons with two Mars orbiters find HyperScout-H’s spectral shape is broadly consistent, while revealing a short-wavelength mismatch and an offset in absolute brightness.

Before Hera reaches the asteroid pair Didymos–Dimorphos, its HyperScout-H camera needs to show that it can measure light reliably. Researchers used Mars as a familiar test target, comparing the camera’s flyby observations with data from two established Mars orbiters. The results suggest the instrument is stable, but also identify calibration differences that matter for interpreting future asteroid images.
A camera heading for an asteroid can be checked against a planet first. During a Mars flyby on March 12, 2025, the European Space Agency’s Hera spacecraft used its HyperScout-H (HS-H) imager to observe the Martian surface. Researchers have now compared those measurements with observations from two long-running Mars orbiters: Mars Express’s OMEGA instrument and Mars Reconnaissance Orbiter’s CRISM instrument. The goal was to test how reliably HS-H measures reflected light before Hera studies Didymos and its moon Dimorphos.
HS-H records light in 25 narrow wavelength bands, from about 0.65 to 0.95 micrometres. That information can help scientists infer what a surface is made of. But comparisons between instruments can be misleading if their measurements differ because of calibration, viewing conditions or processing rather than the surface itself. Cross-calibration looks for those differences so researchers can account for them.
The team analyzed three HS-H images taken during the flyby, selecting 21 Martian surface regions that included varied terrain, such as crater floors, rims and bright or dark areas. They matched these locations to 47 spectra from each of OMEGA and CRISM. The researchers corrected and processed the observations, aligned them by latitude and longitude, and adjusted the reference spectra to reflect HS-H’s particular wavelength bands. They also selected reference observations from a similar season and excluded OMEGA observations with especially high solar incidence angles, which can make a simple brightness correction less reliable.
The comparison separated two questions: Do the instruments capture the same shape of a spectrum across wavelengths? And do they measure the same overall brightness? To compare shape, the researchers first normalized each spectrum around 0.80 micrometres, effectively removing differences in its overall level.
For most of HS-H’s wavelength range, the spectral shapes agreed closely with both reference instruments. The paper reports relative correction factors near one for bands 3–25, spanning 0.688–0.952 micrometres, with differences generally below 1% in the normalized comparison. The two shortest-wavelength bands were an exception: HS-H’s measurements were about 4.7% and 3.6% lower than OMEGA’s. The authors suggest that a temperature-related shift in the camera’s filter response may explain this mismatch. A test shifting the modeled filter profiles by 6 nanometres improved the agreement, but the proposed explanation is not a direct measurement of the filter shift.
When the researchers compared absolute brightness rather than normalized shape, HS-H measured about 8% lower flux than OMEGA, but was within roughly 1% of CRISM overall. The brightness offset between HS-H and OMEGA was nearly wavelength-independent in the analyzed bands, so it did not substantially change the spectrum’s shape. The authors note that OMEGA and CRISM also differ in their absolute brightness measurements; calibration procedures and observing geometry may contribute, and the study cannot determine a single cause for the offsets.
The three HS-H images gave repeatable results: the average variation between images was reported as 0.22% for relative comparisons with OMEGA and 0.20% with CRISM. Repeatability is encouraging, but it is not the same as proving long-term stability. All three images came from one flyby session, and the Mars orbiter observations were taken at other times. Differences in season, viewing geometry and the Martian surface’s departure from idealized Lambertian reflection—the assumption used in the brightness correction—also limit how cleanly the measurements can be compared.
There are practical limits, too. The reported corrections come from averaging roughly 90–105 camera macropixels per region; an individual pixel’s spectrum is noisier and may need averaging before applying the results. The paper also identifies wavelength coverage gaps in the reference data, so not every HS-H band could be checked against both orbiters.
The study’s conclusion is therefore measured: HS-H produced repeatable observations, and its spectral shape broadly matched the Mars instruments across most of its range. The identified short-wavelength discrepancy and absolute-brightness offsets give researchers calibration information to consider when analyzing Didymos–Dimorphos. These Mars tests support readiness, but cannot by themselves establish how the camera will perform over the asteroid system or across a longer period. This article is based on the authors’ arXiv paper; the source and its comparisons have not been independently assessed here.
- Hera mission
- HyperScout-H
- Mars
- cross-calibration
- CRISM
- OMEGA
- hyperspectral imaging
Related reading
Automatically matched by shared topic keywords. These links do not imply that the sources agree or establish a consensus.