TRANSMISSION // 2611.28347v1
A wireless link reads magnons across a gap
Source published
Two microwave ring resonators let researchers detect and influence a magnetic excitation without wiring directly to the resonator that hosts it.

A magnetic excitation can leave a measurable signature in a microwave resonator. In a new experiment, researchers detected that signature through a second ring, separated by a gap and lacking magnetic material of its own.
Reading a magnetic signal from another ring
Magnons are collective excitations of a material’s magnetisation. When a magnon interacts with a microwave photon confined in a resonator, they can form hybrid modes called cavity magnon-polaritons. Researchers commonly identify these modes by measuring changes in a resonator’s reflection or transmission as the magnon frequency is tuned.
Alban Joseph and colleagues investigated whether the hybrid-mode response could be read through a second, separate resonator. Their approach uses inductive coupling: microwave energy can pass between two nearby rings through their electromagnetic fields, without a wire connecting them. The question was whether a magnetic sample on one ring could affect a signal measured at the other.
Two rings and a magnetic sample
The team used planar microstrip ring resonators on circuit-board material, arranged facing one another, and varied the gap between them. They placed a small sphere of yttrium iron garnet (YIG), a magnetic material that supports magnons, directly above the track of one ring. An external magnetic field tuned the magnon’s frequency. The second ring had no magnetic sample.
Using a vector network analyser, the researchers measured microwave reflection and transmission while sweeping the magnetic field. They first characterised the coupling between the empty rings, then examined the YIG sphere’s interaction with a ring and finally measured the two-ring system with the sphere in place. They compared measurements with coupled-mode models and used electromagnetic simulations to check how ring-to-ring coupling changed with separation.
At close spacing, the rings form shared, hybridised photonic modes. As the gap grows, their coupling weakens. The researchers observed that the splitting between modes became unresolved beyond about 10 millimetres, although a transmission band persisted out to 18 millimetres, the largest separation tested. An unresolved splitting does not mean energy transfer has stopped; it means the resonances can no longer be distinguished as separate modes in the measurement.
Readout through the ring without YIG
The magnon’s characteristic response appeared in measurements through the second ring—the one without the YIG sphere. In reflection, the magnetic response was visible at that ring’s port; in transmission, the magnon altered the signal crossing between the rings. For this setup, the authors describe transmission as providing higher-contrast readout than reflection at larger separations. That is a comparison within this experiment, not a general rule for other resonators.
As coupling between the rings fell, the composition of the modes changed: each became more concentrated on one ring. Where the modes could be resolved, the magnon’s coupling became more concentrated in the mode residing on the YIG-bearing ring. Thus, in the measured transmission, the magnon’s influence could increase even as the wireless link itself weakened.
The authors report that the magnon changed transmission by as much as 16 decibels peak-to-peak, with the response tuned by the magnetic field. They also measured the magnon’s contribution to transmission group delay, calculated from the frequency-dependent phase after subtracting an off-resonant background. At an 18-millimetre separation, the reported delay reached +17.8 nanoseconds on one side of the magnon resonance and −31.9 nanoseconds on the other. These are resonant group-delay measurements, not a simple travel time across the gap or a demonstration of communications performance.
What the result does—and does not—show
The work demonstrates that a magnon–photon hybrid response can be read through a spatially separate ring with no magnetic material of its own. Field-tuned changes in transmission also show that the magnon can shape a signal crossing the wireless link. The paper describes remote excitation and readout, but these results do not establish a practical communications device or a quantum information transfer protocol.
The measurements were performed at room temperature using printed-circuit-board resonators. The authors note that, in this setup, energy leaves the rings faster than it can be exchanged with the magnon. They suggest lower-loss resonators could change that balance; this is a possible future improvement, not a result demonstrated in the experiment. The measurements concern one ring design and separations up to 18 millimetres, so they do not establish performance in other layouts or larger arrays.
This article is based on the authors’ version 1 arXiv preprint. The supplied evidence does not establish whether this paper has undergone peer review. The paper lists its data-availability DOI as “TBC.”