Can MRI generate the CT information proton therapy needs?
Source published
A diffusion model turns head-and-neck MRI scans into simulated dual-energy CT images. In a 53-patient study, the images compared favorably with two GAN methods, but clinical benefit remains unproven.

MRI can show soft tissues clearly without ionizing radiation, but it does not directly measure properties needed to plan radiation treatment. Researchers tested whether an AI model could use MRI to generate two types of CT image—and whether those images could support estimates important for proton therapy.
The gap between MRI and treatment planning
Radiation therapy teams use scans to plan where radiation should go and how much tissue will receive it. MRI is good at showing soft tissues, including tumors, and does not use ionizing radiation. But MRI does not directly provide some material measurements used in treatment calculations. That matters especially in proton therapy: estimates of how tissue slows protons help predict where the particles deposit their energy.
Dual-energy CT (DECT) captures images using two X-ray energy ranges. Those images can help distinguish tissue properties and estimate the stopping-power ratio (SPR), a measure used in proton planning. But DECT involves radiation exposure. The study asks whether a model could generate both high- and low-energy CT-like images from MRI, potentially providing related information without acquiring DECT for that purpose.
Training a model to make two images
The researchers used retrospective, paired MRI and DECT scans from 53 people with head-and-neck cancer who had imaging for proton-therapy planning. The scans were taken on the same day. Before training, the MRI volumes were registered to match the DECT images; medical physicists reviewed the registrations. The team randomly assigned patients—not individual image patches—to training, validation, and test sets, with roughly 70%, 10%, and 20% of patients in each.
Their denoising diffusion probabilistic model (DDPM) was trained to generate synthetic high-energy and low-energy CT images from an MRI volume. In broad terms, diffusion models learn to reverse a process that adds noise to images, gradually turning noise into an image. Here, MRI provided the patient-specific conditioning information. The team tested two model designs, SwinViT and ResUNet, and compared them with Pix2PixGAN and CycleGAN, two types of generative adversarial network (GAN).
They assessed the synthetic images against the corresponding real DECT using image-similarity measures, including mean absolute error (MAE), structural similarity (SSIM), and normalized cross-correlation (NCC). They also examined image differences, anatomical profiles, variation across repeated generated images, and SPR maps calculated from the synthetic images. This last step tested whether the model’s output retained information relevant to proton planning—not whether treatment itself became more accurate.
What the study found
The diffusion models scored better overall than the two GAN approaches on the reported image-quality measures. For the better-performing SwinViT version, mean absolute error was about 36 HU for the high-energy image and 44 HU for the low-energy image. SSIM was 0.89 and 0.87, respectively; scores closer to 1 indicate greater structural similarity. The authors also reported that anatomical boundaries were generally preserved, while noting that bone intensities tended to be underestimated and errors were more pronounced around complex bone and soft-tissue boundaries.
SPR estimates derived from the SwinViT synthetic images had a mean normalized absolute error of about 3.6% in the test set. The authors describe the SPR uncertainty and errors as within an expected acceptable range. These findings suggest the generated images may preserve useful tissue-related information in this dataset. They do not establish that using the images would improve dose delivery or patient outcomes.
What remains uncertain
The evidence is retrospective and comes from a small, single anatomical region: head and neck. The model was trained on one MRI sequence, and the study used scans from one proton-therapy planning context. Performance may differ across hospitals, scanners, patient groups, MRI protocols, or body regions. The researchers themselves identify these as areas for further testing.
There are practical and technical caveats. Producing one synthetic volume took about 240 seconds, compared with roughly 10 seconds for the GAN alternatives. The authors also warn that image-to-image translation can produce an image that looks convincing but is physically inaccurate, particularly where MRI provides limited information about tissue composition, such as bone, calcification, or metal implants. Registration errors could also affect comparisons between MRI and DECT.
Most importantly, the study did not directly test whether the method improves proton dose calculations or range accuracy. That requires dedicated validation. The article is an arXiv preprint, so its claims should be treated as preliminary rather than as established clinical evidence. The results support further investigation of MRI-to-DECT synthesis; they do not show that DECT can already be safely replaced in routine care.
- MRI
- dual-energy CT
- proton therapy
- diffusion models
- radiotherapy planning
- stopping-power ratio
Related reading
Automatically matched by shared topic keywords. These links do not imply that the sources agree or establish a consensus.
How separate image generators can make coordinated outputs
Source published
Shared keywords: diffusion models
Quantum amplitude estimation tests a proton-transport model, but clinical speedup remains out of reach
Source published
Shared keywords: proton therapy
How guidance can activate hidden errors in diffusion models
Source published
Shared keywords: diffusion models
A new way to steady reward training for diffusion models
Source published
Shared keywords: diffusion models
A diffusion model may need guidance only while it is reading the prompt
Source published
Shared keywords: diffusion models