Teaching segmentation AI to follow an endoscopist’s gaze

Source published

GEG-SAM combines gaze trajectories and image content to guide polyp segmentation. The preprint reports gains on five public datasets, but clinical usefulness remains untested.

AI-generated conceptual illustration for Teaching segmentation AI to follow an endoscopist’s gaze
AI-generated conceptual illustration; not documentary evidence.

A clinician’s eye movements can reveal what they inspected during a colonoscopy. A new preprint uses that signal to guide an image-segmentation model—not as a set of isolated points, but as a connected visual search. Its results are promising, though they come from benchmark datasets rather than a clinical trial.

During a colonoscopy, an endoscopist’s gaze moves across the image as they inspect tissue. Could those eye movements help train AI to outline polyps, without requiring manual masks during training? A team led by Ao Wang proposes GEG-SAM, a method that uses gaze and image information to guide a pretrained segmentation model.

A fixation—a spot where someone looks—does not necessarily identify a lesion on its own. Its meaning may depend on what the person looked at before and after, how it relates to other fixations, and what appears in the image at that location. Treating each fixation as an independent target could give a model misleading guidance.

GEG-SAM represents gaze as a sequence, capturing timing and spatial relationships among fixations. It combines those relationships with visual features from the corresponding image regions, then uses the resulting signals to influence features inside SAM3, a pretrained segmentation model. The SAM3 encoder remains frozen while added components that interpret and inject gaze information are trained. Fixations selected according to their duration also serve as positive prompts for SAM3 to generate pseudo-masks. These automatically generated masks provide training supervision; the paper says manual masks are not used during training.

The researchers evaluated the method on five public colonoscopy image datasets: Kvasir-SEG, CVC-ClinicDB, CVC-ColonDB, CVC-300 and ETIS. They report using 1,450 images from two datasets for training, with the remaining 162 used for in-domain testing. Three other datasets served as unseen test sets. Gaze annotations for Kvasir-SEG came from an existing dataset. For the other datasets, the team collected gaze data from experienced endoscopists using an eye tracker.

GEG-SAM with SAM3 achieved a reported mean Dice score of 86.43% across the five datasets. Dice measures overlap between a predicted outline and a reference mask; higher scores indicate greater overlap. The authors report a 9.30-percentage-point gain over the strongest weakly supervised baseline in their comparison. This is the paper’s reported benchmark comparison, not an independently verified ranking of methods.

The team also tested GEG-SAM with SAM-Base, SAM-Large and SAM-Huge, reporting mean Dice scores of 85.23%, 85.99% and 85.94%, respectively. These results suggest that the approach worked with the tested SAM backbones, not only SAM3.

Ablation experiments removed or changed parts of the system to examine their contributions. The paper reports that combining the temporal and spatial branches of its gaze encoder performed better than using either branch alone. Its component tests also report improved results when gaze relationships, image context and the feature-injection module are combined. These results support the design choices in the tested setup, but do not by themselves prove why the method performs as it does or establish its effect in clinical practice.

Important limits remain. The evaluation used public image datasets, not a prospective study in which the system assists clinicians during real procedures. The paper does not demonstrate improved diagnosis, patient outcomes or clinical workflow. Performance on other populations, equipment and clinical settings is uncertain. The authors describe continuous endoscopic video segmentation as future work, so these image-based results do not establish performance on video over time.

This work is an arXiv preprint; the supplied source does not establish its peer-review status. Its findings are best read as an early technical result: structured gaze may help guide weakly supervised polyp segmentation on these benchmarks, while independent testing and clinical evaluation are still needed to establish practical value.

Reviewed cross-references

These connections were reviewed by a model, not independently fact-checked by a human. Similarity does not imply agreement; consult the original papers and the evidence below.

  • Using two-channel hearing to identify which object is making a sound

    Shared method: Both methods keep a pretrained SAM image encoder frozen and add task-specific spatial conditioning to guide segmentation features: GEG-SAM injects gaze-conditioned tokens, while BiSID-AVS uses binaural spatial cues at feature and decoder levels. This is a shared design pattern, not evidence of comparable performance; the tasks, inputs and evaluation settings differ.

    Model review: · openai-codex/gpt-6-luna

    Evidence and provenance

    Selected excerpts, not complete papers. PDF extraction can omit figures or damage equations, tables and reading order; sources may be preprints.

    • 2611.27183v1 — Original paper

      Excerpt reference: static/papers/2611.27183v1.md:170-237
      Basis: Paper text
      Source SHA-256: 39323bd703b4caddb0b311a4532f9d59c2b0066d95917d9d1111bcbe5ea3d39e

    • 2611.06074v1 — Original paper

      Excerpt reference: static/papers/2611.06074v1.md:1001-1106
      Basis: Paper text
      Source SHA-256: b19e085187e61087f9c1a44fdda51959082bff9cfc02154a35402421f9837197

Automatically matched by shared topic keywords. These links do not imply that the sources agree or establish a consensus.