TRANSMISSION // 2611.26794v1
Teaching pathology AI to show its work
Source published
HERMES combines two kinds of tissue images and checks intermediate measurements against cell-level data. It outperformed the 12 compared MLLM baselines on four tumor-immune tasks, but the findings do not establish clinical readiness.

A tissue image can show where cells are, but not necessarily which cells carry a particular marker. A new preprint tests whether pairing two imaging methods—and checking each step in an AI model’s stated reasoning—can improve measurements of the tumor immune microenvironment.
Why combine two kinds of tissue image?
Pathologists studying a tumor’s immune microenvironment need to know both where cells sit and what they are. Hematoxylin and eosin (H&E) staining shows tissue structure, including the boundary between tumor epithelium and surrounding stroma. Multiplex immunofluorescence (mIF) identifies proteins in individual cells, helping distinguish CD8-positive immune cells or cells positive for the proliferation marker Ki67.
Neither image alone provides the whole picture. H&E does not identify a cell’s marker proteins; mIF may show those proteins without clearly identifying the relevant tissue compartments. The authors argue that this makes it difficult for AI systems to estimate readouts such as immune-cell density, the location of immune cells in tissue, or the Ki67 index.
A second concern is whether an explanation supports a model’s answer. A plausible final answer does not guarantee that the measurements stated along the way are correct. The researchers tested whether an AI system could read paired H&E and mIF images, follow steps based on clinical scoring guidance, and have those steps checked against cell-level measurements.
How HERMES was trained and tested
The team developed HERMES, a 4-billion-parameter multimodal language model. For each task, it receives images of the same tissue field from H&E and mIF. Its structured response names the image used at each step, reports quantities such as epithelial area or the number of marker-positive cells, and then gives an answer.
The training data came from a colorectal cancer imaging cohort. Cell tables and tissue masks provided reference values for intermediate steps, such as the number of positive cells inside a compartment. The model first learned from examples filled in with those values. It was then trained with reinforcement learning that rewarded the final answer and checked stated intermediate quantities against the reference measurements. The model did not receive the ground-truth values as input when answering.
The researchers evaluated four field-level tasks: CD8-cell density; identifying and boxing regions containing intra-epithelial CD8-positive cells; whether Ki67-positive cells were mainly epithelial; and the fraction of epithelial nuclei positive for Ki67. For the Regions task, the main task-accuracy metric assessed whether intra-epithelial infiltrates were present, while the quality of the predicted boxes was evaluated separately. On the main colorectal cancer test, the team compared HERMES with 12 general, medical, pathology-focused, and proprietary MLLMs. They also tested it without retraining on two external cohorts: another colorectal cancer cohort imaged with CODEX, and a head and neck cancer cohort not represented in training.
What the study found
On the main test, HERMES achieved an average accuracy of 84.5% across the four tasks. The strongest of the 12 MLLM baselines scored 74.7%. A separate task-specific foundation-model baseline, which produced readouts without intermediate explanations or boxes, scored 80.4%. HERMES also got a larger share of its intermediate quantities right than the strongest open-weight MLLM baseline: 66.2%, compared with 16.4%.
The process reward—the part that checks the steps—appeared important. Starting from the same supervised model, reinforcement learning without that reward raised average accuracy from 78.8% to 80.0%, while the full approach reached 84.5%. Without process supervision, fewer intermediate quantities were correct, and the model sometimes departed from the intended steps.
The researchers tested whether answers followed the quantities HERMES stated. In an editing test across 885 questions, changing a decisive stated quantity changed the answer in the way implied by that edit. Separately, removing CD8-positive cells from an mIF image usually lowered the model’s stated count. These experiments support a link between stated measurements and answers; they do not establish that every explanation reflects the model’s internal processes in every setting.
Without retraining, HERMES’s average accuracy was 76.4% on the external CODEX colorectal cohort and 76.7% on the head and neck cohort. The strongest MLLM comparison scored 67.3% and 72.5%, respectively. This is evidence of transfer across these particular datasets, not proof of broad generalization.
What remains uncertain
The main test included five held-out patients, with model comparisons based on sampled field-level questions. The external cohorts broaden the evaluation, but they remain specific datasets and tasks. Results may depend on image preparation, cell segmentation, marker thresholds, and how tissue compartments are defined. The reference measurements enable checks against the study’s labels; they do not establish how well outputs align with expert assessment or clinical use across settings.
The work is an arXiv preprint and may not have undergone peer review. Its findings concern image-based measurements in defined experiments; they do not show that HERMES improves diagnosis, treatment decisions, or patient outcomes. Further validation would be needed before treating it as a clinical tool.
The study’s central contribution is a way to make some image-based reasoning more measurable: when paired images and cell-level data are available, intermediate quantities can be checked rather than judging only the final answer. Whether the approach remains reliable across institutions, imaging workflows, and additional cancers is still an open question.
- computational pathology
- tumor immune microenvironment
- H&E
- multiplex immunofluorescence
- multimodal AI
- process supervision
Reviewed cross-references
These connections were reviewed by a model, not independently fact-checked by a human. Similarity does not imply agreement; consult the original papers and the evidence below.
Can One AI Agent Learn From a Whole Team?
Shared method: Both studies use process-level supervision to shape model reasoning: HERMES rewards stated quantities against cell-level measurements, while AgentArk uses process-aware distillation with a process reward model. The shared method is bounded to supervising intermediate reasoning; the tasks, supervision sources and model setups differ, so their results are not directly comparable.
Model review: · openai-codex/gpt-6-luna
Evidence and provenance
Selected excerpts, not complete papers. PDF extraction can omit figures or damage equations, tables and reading order; sources may be preprints.
2611.26794v1 — Original paper
Excerpt reference:
static/papers/2611.26794v1.md:13-87
Basis: Paper text
Source SHA-256:08fb07446a5466964fda2684d91bda123d254b93c974716a32f02c32bf6af13e2602.03955v4 — Original paper
Excerpt reference:
static/papers/2602.03955v4.md:61-108
Basis: Paper text
Source SHA-256:4629ab39e70e75e963bf5edecbde2e77a2475bb747eefa5ef2cbe17a18cf2691
Related reading
Automatically matched by shared topic keywords. These links do not imply that the sources agree or establish a consensus.
Can combining biopsy images and clinical data improve predictions in inflammatory bowel disease?
Source published
Shared keywords: computational pathology, multimodal ai
A compact way to search growing pathology image archives
Source published
Shared keywords: computational pathology
Linked tokens aim to speed multimodal AI
Source published
Shared keywords: multimodal ai
A new way to keep multimodal AI’s interactions in check
Source published
Shared keywords: multimodal ai
Why Multimodal AI Can Forget in Two Places
Source published
Shared keywords: multimodal ai