Mechanical sensor noise may depend on size, not Q
Source published
An arXiv preprint reports that mechanical resonator flicker noise scales inversely with strain-weighted volume and is independent of measured quality factor after accounting for Q–volume covariance.

Mechanical resonators can sense added mass through shifts in their vibration frequency. But persistent 1/f, or flicker, frequency noise can limit how clearly those shifts are measured. An arXiv preprint argues that this noise is linked to resonator volume and defect density, rather than independently to quality factor.
Mechanical resonators vibrate at characteristic frequencies. A change in mass can shift those frequencies, making the devices useful as sensors. Yet frequency noise with a 1/f spectrum—often called flicker noise—can obscure small shifts and keep sensors from reaching the resolution predicted by thermomechanical or quantum limits, the preprint says.
The paper asks what sets this noise floor. Its abstract reports a comparison across the published record: the product of the flicker-noise coefficient, h₋₁, and a strain-weighted resonator volume, Vε, is size-independent across 13 decades. It also reports that the noise is independent of measured quality factor, Q. The author argues that covariance between Q and volume explains reported Q-dependence: if two properties vary together, an apparent association with one may reflect their relationship with the other.
The abstract attributes the frequency-noise floor to defect density. It says prestress can dilute the noise, but only in fixed-end devices. It also reports that mass resolution scales as |δm| ∝ √V. The abstract does not give the conditions or derivation for this scaling; that information is unavailable in the supplied evidence, so the relationship should not be treated here as a general design rule.
What the result may mean
If the reported Q-independence holds, improving Q alone would not necessarily lower this flicker-noise floor. That is an implication of the abstract’s claim, not a separately demonstrated design result in the evidence available here. The reported roles of volume, defect density and prestress point to other factors worth considering, with the prestress result specifically limited to fixed-end devices.
This account is based on the abstract only. It does not provide enough detail to assess how the measurements were selected or analyzed, how uncertainties were handled, or how competing explanations were evaluated. Those details may be addressed in the full paper, but cannot be checked from the supplied abstract. The source is an arXiv preprint; the available evidence does not establish its peer-review status. Its claims should therefore be understood as the author’s reported analysis, not as settled consensus.