TRANSMISSION // 2605.22414v3
How retinal AI can connect answers to evidence
Source published
FundusGround evaluates retinal-image question answering alongside lesion type and location, and reports that lesion-supervised training often improves model scores in its experiments.

A model can answer a question about a retinal image without making clear which visible findings it used. FundusGround is a benchmark that evaluates answers alongside reported lesion types and locations, then compares models trained with and without lesion-level supervision.
Why connect answers to retinal evidence?
Retinal fundus photographs show the back of the eye, where signs of conditions such as diabetic retinopathy and age-related macular degeneration may appear. For medical question-answering systems, a plausible answer alone does not reveal whether the model identified relevant features in the image. FundusGround, introduced in this preprint, is designed to assess answers and lesion-level evidence together.
The researchers evaluate vision-language models on questions about fundus images, measuring answer performance and whether reported lesion types and locations match annotations. They also compare fine-tuning with answer supervision alone against training that includes lesion-level supervision. This tests how the added supervision affects these benchmark measures; it does not establish that a model’s stated evidence faithfully describes its internal reasoning.
Building the benchmark
FundusGround contains 10,719 images assembled from 10 publicly available ophthalmic datasets, as well as additional in-house data for pathological myopia. The images cover several disease categories and include images labeled normal. The authors curated 15,595 lesions using annotations from the underlying datasets. These include vascular and exudative findings, structural lesions and other abnormalities.
To standardize location, the team mapped lesions onto the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. The grid has a central macula and inner and outer rings, each divided into four directional quadrants. When anatomical landmarks were not already annotated, a detection model estimated the optic disc and fovea; people reviewed and corrected those estimates. Ophthalmologists also reviewed ambiguous lesion-to-region mappings.
The team generated questions in four formats: open-ended, closed-ended, single-choice and multiple-choice. GPT-5 produced candidate questions from the structured annotations. Rule-based checks and Qwen3.5-assisted screening helped remove queries judged unanswerable, ambiguous or clinically implausible. Ophthalmologists reviewed a subset and their feedback was used to refine filtering. The resulting benchmark contains 72,706 questions across training, test and external-validation sets. The paper states that no images or questions from the two external datasets were used during training; it does not establish that all related data were absent from training.
What the model comparisons show
The researchers tested general-purpose and medical vision-language models in three settings: zero-shot answering, fine-tuning on answers alone, and fine-tuning on answers plus lesion evidence. In the last setting, models were trained to report lesion types and ETDRS locations as well as an answer.
The reported results generally favor lesion-level supervision, but gains vary by model, question format and evaluation set. The paper’s tables include exceptions, including external-set open-ended answer scores that do not improve for some models. In one test-set comparison, MedGemma-1.5’s multiple-choice answer score was 26.47 percentage points higher with lesion supervision than with answer-only fine-tuning. In that lesion-supervised setting, its lesion-type and lesion-location scores were 43.49% and 33.11%, respectively.
These results show that the training setup can affect both answer scores and the model’s ability to produce lesion labels and locations that match the benchmark annotations. Those measurements do not by themselves establish that the reported evidence truly supports an answer, or that it reveals the model’s internal reasoning. The authors’ case study also notes that predicted lesion locations did not fully align with the ground truth, even where lesion supervision improved the answer.
Limits and what comes next
FundusGround is a benchmark study, not a clinical trial. Its results do not show that using these models improves patient outcomes or that the systems are ready to guide diagnosis. Performance on these curated images and questions may not transfer to other cameras, clinics, populations or workflows.
Some evaluation choices also matter when interpreting the scores. GPT-4o was evaluated on a random sample of 100 cases per task because of API constraints. Open-ended answers were scored with BLEU-1, a measure of word overlap that may not capture every clinically acceptable answer. Expert review covered a subset of generated questions, rather than every question, according to the paper.
The work is an arXiv preprint, so its claims have not necessarily undergone independent journal peer review. The authors say the dataset and question-generation prompts will be released upon acceptance. Until then, the findings should be understood as results from the evaluation described in the paper, not as settled evidence of clinical utility.
- ophthalmology AI
- retinal imaging
- visual question answering
- FundusGround
- lesion localization
- medical AI
Reviewed cross-references
These connections were reviewed by a model, not independently fact-checked by a human. Similarity does not imply agreement; consult the original papers and the evidence below.
AI checks chest X-rays globally, then inspects regions to explain its reports
Shared method: Both works spatially associate visual evidence with anatomical regions to make model outputs more inspectable: FundusGround maps retinal lesions to ETDRS regions, while ARIVE uses inspected chest-X-ray regions to inform diagnostic reasoning. The implementations and tasks differ—lesion-grounded VQA versus report generation—so this is a methodological connection, not evidence of comparable performance.
Model review: · openai-codex/gpt-6-luna
Evidence and provenance
Selected excerpts, not complete papers. PDF extraction can omit figures or damage equations, tables and reading order; sources may be preprints.
2605.22414v3 — Original paper
Excerpt reference:
static/papers/2605.22414v3.md:69-132
Basis: Paper text
Source SHA-256:5336697fde25996e8a07ace929ada600cbde8c9ccbc7976ad8b5ee888a8ac58a2611.14018v1 — Original paper
Excerpt reference:
static/papers/2611.14018v1.md:109-134
Basis: Paper text
Source SHA-256:59f05fde63bb9bea6e7afc61f2c1728b848ba5d4cfc5d59e9660b51c444d61bd
Related reading
Automatically matched by shared topic keywords. These links do not imply that the sources agree or establish a consensus.
When eye-screening rules leave gaps, what does AI learn?
Source published
Shared keywords: retinal imaging
A structured benchmark for AI and everyday skin photos
Source published
Shared keywords: visual question answering
A broader test for medical AI recommendations
Source published
Shared keywords: medical ai
MedicalRSI aims to help medical AI learn from mistakes
Source published
Shared keywords: medical ai
Glyph turns hidden medical AI features into testable disease-risk clues
Source published
Shared keywords: medical ai